Act D'MAND Kontrols® System 3-Speed Pump Model
C3-100-PFS
For standard plumbing systems
Composite pump
Small stator motor
1hp
115v
PF Kit and Small Mounting Bracket included
Recommended for use with standard plumbing systems in buildings up to
4,000 sq. ft. with tank water heaters. Or pipe runs up to 60 lineal
ft.
Is this the right model for you? See sizing
This product can be used on new homes or existing homes.
• Saves water, energy, time, and money
• Reduces sewage processing
•
Reduces carbon footprint
• Equipped with
3/4" composite MIP male adapters for easy install
•
Maintenance free
• Operational cost of
less than $1 a year
• Increases the life of
any water heater up to 25%
• Life expectancy
of 20 years
The D'MAND Kontrols® C3-Series converts standard plumbed homes into D'MAND
Kontrols® Systems. At the push of a button, the C3-Series pumps cold water
sitting in the hot water line into the cold water line and back to the water
heater. The "temperature sensor" automatically shuts off the pump allowing the
pump's IFC (Integral Flow Control) Valve to close when hot water arrives at the
fixture. Now you have hot water within seconds at the fixture and anywhere
else plumbed off of the main line.
The C3 series models are recommended for use with standard plumbing systems
in buildings up to 4,000 sq. ft. with tank water heaters. Or pipe runs up to 60
lineal ft. between a tankless water heater and installation location of the
D'MAND KONTROLS® System.
The patented PDV (Check Valve) is built right into the pump housing, reducing
the number of external devices. It is suitable for runs up to approximately 100
feet.
Product Warranty: 5 Year Manufacturer Warranty
C3-100-PFS Includes:
• Composite pump
•
Electronic circuit board
• Thermosensor
mounted in composite volute
• 3/4" CPVC
threaded connections
• Internal check
valve
• Includes one hard-wired activation
button (chrome)
• Pre Fabrication Kit
(PF):
Two (2) stainless steel
3/4" ID,
18"
corrugated flex lines with threaded male/female ends
Two
(2) custom machine tooled no lead brass T's
• Small mounting bracket MB-CS-SS-SM
Weight: 8 lbs.
Dimensions: 5.25" wide,
5.25" deep, and 4.75" tall
C3-100-PFS D’MAND Kontrols® Systems can be used with both
tank and tankless water heaters on standard plumbing in existing homes,
new home construction or light commercial applications. At the push of a
button, or with a motion sensor in place, the D’MAND Kontrols® System
activates and pumps the ambient (cool) temperature water back to the water
heater saving both water and energy in the process. When the hot water
arrives at the D’MAND Kontrols® System, the built-in thermistor
automatically shuts the pump off and closes the IFC Valve. Now you have hot
water within seconds at the fixture and anywhere else plumbed off the main
line.
C3-100-PFS models are designed for use in large homes or
commercial buildings where the distance from the water heater to the farthest
fixture is greater than 120 feet. This model is adaptable to any tankless water
heater.
Downloads |
Data
Sheet . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . Installation
Manual . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . Accessory
Guide . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . |
|
|
SIZING GUIDE |
Standard Plumbing |
C3-100-PFS |
S3-100-PFS |
BR3-200-PF |
Composite
Pump |
Stainless
Steel Pump |
Bronze
Pump |
Homes
up to 4,000 sq ft |
Homes
up to 4,000 sq ft |
Homes
OVER 4,000 sq ft |
Pipe
runs up to 60 lineal ft. between a tankless water heater and installation
location of the D'MAND System |
Pipe
runs up to 100 lineal ft. between a tankless water heater and installation
location of the D'MAND System |
Pipe
runs OVER 100 lineal ft. between a tankless water heater and installation
location of the D'MAND System |
Structured Plumbing - Dedicated Return
Line |
C3-100 |
S3-100 |
BR3-200 |
Composite
Pump |
Stainless
Steel Pump |
Bronze
Pump |
Homes
up to 4,000 sq ft |
Homes
up to 4,000 sq ft |
Homes
OVER 4,000 sq ft |
Pipe
runs up to 120 lineal feet |
Pipe
runs up to 200 lineal feet |
Pipe
runs OVER 200 lineal feet |
Nomenclature Guide |
TYPE
KEY |
Example |
C |
S |
BR |
3 |
100 |
200 |
PFS |
C:
Composite Pump |
|
|
|
|
|
|
S:
Stainless Steel Pump |
|
|
|
|
BR:
Bronze Pump |
|
|
3:
3 Speed |
|
|
|
|
|
100:
100 Series Small Stator Motor |
|
200:
200 Series Large Stator Motor |
PFS:
Pre Fabrication Kit - Under sink installation kit includes custom T's &
Flex Lines and Small Mounting Bracket |
ACCESSORIES |
Activation
Accessories |
|
|
HWMSRB-W Hard-wired
Motion Sensor, White. More
info |
|
|
HWMSRB-B Hard-wired
Motion Sensor, Black. More
info |
|
|
WRT-KIT Wireless
Transmitter and Receiver. One hard-wired receiver and one wireless
transmitter. More
info |
|
|
WMSCB-KIT Wireless
Motion Sensor Kit - Curtain Beam One hard-wired receiver and one wireless
motion sesor. More
info |
|
|
WMSRB-KIT Wireless
Motion Sensor Kit - Round Beam One hard-wire receiver and one wireless
motion sensor. More info |
Activation
Buttons |
|
|
HWB-S - Standard
Button (Gold or Chrome) HWB-G-S - Standard Button: Gold HWB-CH-S -
Standard Button: Chrome HWB-CH-LED - LED Illuminated |
Button Wall Plates |
|
|
BP-W - White BP-B -
Black BP-STS - Stainless Steel |
Product Manufacturer: ACT, Inc.
Advanced Conservation Technology, Inc. (also known as, ACT, Inc. D'MAND
Kontrols Systems®) manufactures Hot Water Recirculation Systems that deliver
hot water on demand, reduce water waste, and conserve energy. ACT, Inc.'s
D'MAND Kontrols® recirculating hot water pumps send cold water in the plumbing
back to the water heater, via the cold water, or dedicated return line, while
simultaneously bringing hot water to all fixtures in the line, in a matter of
seconds. Unlike other hot water recirculation pumps, the D'MAND Kontrols
Systems® do not allow hot water into the cold water line, and deliver hot water
to the furthest fixtures on user demand, rather than relying on a timer
activated system.
Notes on Activation
The D’MAND Kontrol pump can be activated by a hardwire push button, hardwire
motion sensor, wireless remote, or wireless motion sensor. The pump comes with
1 hardwire push button which wires back to the pump via low voltage wire (CAT
5 or doorbell wire). The user can order as many additional push buttons as
desired; all buttons have to be wired back to the pump using low voltage
wire.
For users who are retrofitting the pump into their homes and cannot run wire
to the pump, The pump has wireless remote activators and wireless motion sensor
activators. ACT, Inc.'s D'MAND Kontrol® activation methods allow it to be the
best performing on-demand pump on the market.
You can use the hardwire push button in tandem with the wireless remote
activator or the wireless motion sensor, You CANNOT use any motion sensor
(wireless or hard wired) with the wireless remote activator. The reason for
this is that the wireless remote activator uses a 5-Volt activation switch
within the pump and the motion sensor uses a 12-Volt activation switch within
the pump. You can use as many wireless remote activators as desired, and up to
10 wireless motion sensors per wireless receiver.
Processing and Delivery Information: Please allow Processing
Time as stated above for your order, plus standard transportation delivery
time. Orders placed after 2PM EST may not begin processing until the next
business day. Please call for Rush Processing and/or Rush Shipping
options.