Where the World Shops for Energy
  Home » Shop » KC4500-00 LogIn  |  CheckOut   
Categories
Solar PV Electric
Water Heaters
Space Heating
Pool Heaters
Pool and Spa
Lighting
Water Conservation
Wind Power
Energy Savings
Outdoor Lifestyle
Preparedness
Gadgets
Parts & Supplies
Great Gift Ideas!
Clearance and Sales
New Arrivals
Information
LIVE SUPPORT
9am - 5pm EST M-F
800 333 9276
941 360 9276
Sales Support
Tech Support
Contact Info
Legal | Policies
Mailing List
Name:

Email Address:

Add:
Remove:
Manufacturers
Currencies

Solar Direct, Inc. is a BBB Accredited Business. Click for the BBB Business 
Review of this Solar Energy Equipment & Systems Dealers in Sarasota FL
Credit Card Processing


 © 2022 Solar Direct
 All Rights Reserved
KC4500-00 Vernatherm Freeze Protection Valve 35F Discharge 0.50 Inch *OUT OF STOCK*
   Model: KC4500-00
KC4500-00 Vernatherm Freeze Protection Valve 35F Discharge 0.50 Inch *OUT OF STOCK*
CLICK dropdown arrow in selection boxes to
    configure product and determine total cost.

Base Price:  $58.95
    Shipping based on delivery destination:
     
        For Shipments Outside of the Contiguous US please Contact Us for a Quote
            Optional Installation Services
            Tell Someone About This Great Deal!
            Found a lower price? Let us know![?]
This Item Is Currently Out Of Stock



    Vernatherm Freeze Protection ValveVernatherm Freeze Protection Valve Model KC4500-00, 35F Discharge

    _____________________

    WARNING: See critical warning below relating to proper selection of valve model related to application.
    _____________________

    Keep your solar collectors and exposed pipes from freezing with the Vernatherm solar freeze protection valve

    The Vernatherm valve contains a thermal actuator that opens the valve when the temperature approaches freezing and re-closes it upon warm up. This is a continuous process of modulation; cold water is discharged and replaced by warmer water preventing panel and piping freeze up.

    This valve features a patented anti-seize feature which ensures longevity and durability you can depend on, through the years this valve will not seize due to corrosion, and will continue to function.

    Freeze protection valves use reliable, non-electric, self-contained paraffin wax motors (thermal actuators) which automatically respond to temperature fluctuations. Usually in freeze protection applications, the valve port opens on temperature drop, allowing liquid that would normally freeze to be discharged and replaced with warmer fluid within the system.  When warmer temperatures are detected by the thermal actuator within, the valve will automatically close the valve and the discharge cycle stops.

    This cycle will repeat as often as necessary to prevent freezing.  The amount of fluid discharged depends on ambient air temperature, and fluid temperature.  The system is functioning properly when fluid is being discharged from the valve in near freezing conditions. The Vernatherm valves features sets these valves apart from the competition!

    Product Features
    ˝" Male NPT Fitting
    Anti-seize feature ensures longevity and durability
    Anti-insect design prevents any insect from making this valve
       its home and causing a failure
     Compact design for easy install - weighs only 4oz
    UV resistant body material
    Stainless steel inlet debris screen
    Discharge temperature set to 35F
    Internal filter screen
    FDA and NSF listed materials
    100 psi maximum operating pressure
    Complete mechanical operation
    Tamper resistant design
    Corrosion resistant materials
    Non-electric function

    Product Application: Solar Domestic Water Heating System

    Product Function:
    Protects solar collectors and exposed piping from freezing


    _______________________________________________________

    HELP » Contact Customer Support
    Toll-Free help line offering product info and ordering support
    Online e-mail technical and installation support
    _______________________________________________________

    A typical solar domestic water heating system components and layout is shown below.






    _______________________________________________________

    Download » Vernatherm Valve Data Sheet

    NOTE: During cold weather, it is normal for the valve to dispense water from its discharge port even when ambient air temperatures are several degrees above freezing.

    _______________________________________________________

    Product Warranty: 1 Year Manufacturer Warranty

    Product Manufacturer: Rostra Vernatherm, LLC


    WARNING: Solar collectors can reach internal temperatures up to 10 degrees below the outside ambient air temperature. Standard Active Open Loop Solar Systems typically require a 45F valve to ensure proper protection. Passive Batch or Integrated Collector Storage (ICS) systems such as the ProgressivTube have a much larger volume and mass of stored water, and will not freeze as quickly as a Active Open Loop Solar System, therefore they can typically utilize a 35F valve.

    This condition results from a phenomenon known as "night-sky emissivity". The emissivity of a material is the ratio of energy radiated by the material (solar panel) to energy radiated (or absorbed) by a black body (the sky); it is a measure of a material's ability to absorb and radiate energy.

    Since solar collectors are coated with a black surface they are very good at conducting and emitting energy. When the outside temperature approaches freezing, the surface of the solar collector begins to emit energy to the night sky. When the atmosphere is clear with no clouds, the transfer of energy is accelerated.

    In layman terms, this means that on a cold clear night, the water in the solar panel can be up to 10 degrees colder than the outside temperature. A Freeze Protection Valve needs to begin opening when the outside temperature drops to 42 degrees and below. As the temperature drops from 42 to 32 the volume of water discharged from the valve increases.

    Consult the owner's manual of your collector and/or system to determine the correct valve model to use; Solar Direct and/or The Energy Supermarket makes no claim as to the correct valve to use, and/or its usage and application; and assumes no liability for damages resulting from correct or incorrect use of this product.

    WARNING: Do not expose valves to temperatures above 300F (148.8c) as this may damage the valve.

    Processing and Delivery Information: Please allow Processing Time as stated above for your order, plus standard transportation delivery time. Orders placed after 2PM EST may not begin processing until the next business day. Please call for Rush Processing and/or Rush Shipping options.

Reviews This Item Is Currently Out Of Stock

Customers who bought this product also purchased
Goldline GL-30 Solar Control Package with Sensors
Goldline GL-30 Solar Control Package with Sensors
LFN36-M1 Watts Vacuum Breaker
LFN36-M1 Watts Vacuum Breaker
Goldline GL-30-LCO Solar Control Package with Power Cord and Sensors
Goldline GL-30-LCO Solar Control Package with Power Cord and Sensors
Goldline Solar Recirculation Sensor - Model: GLSB-10k
Goldline Solar Recirculation Sensor - Model: GLSB-10k
VT2212G13B020 Erie Motorized Zone Check Valve 1/2 inch fittings. Sweat Connections
VT2212G13B020 Erie Motorized Zone Check Valve 1/2 inch fittings. Sweat Connections
Shielded Sensor Wire. 50 or 100 feet Coil. Model SW
Shielded Sensor Wire. 50 or 100 feet Coil. Model SW
Quick Search
Enter keywords

• Advanced Search
View all Products
View Cart more
0 items
Manufacturer Info
Other products
Invest in Solar
Promote Solar
Installations more
Professional installation available for most products.
Call us today for custom orders & installation quotes.
Solar Affiliates
Solar Affiliate Program

Affiliate Log In
Solar Affiliate Program
Great Deals
T-Shirts
Tell A Friend
 
Tell someone you know about this product.
Connect with Us
      follow us 
on facebook Facebook
      follow us on twitter Twitter
      

12