Includes control unit only.
Please click below for other options:
Control
Unit with power cord Control
Unit with sensors Control
Unit with power cord and sensors Goldline GL-30 Solar Control Unit - 110
Volts
The Goldline GL-30
differential temperature control is designed to provide maximum operating
efficiency and flexibility to effectively manage today's innovative solar energy
systems. It is a continuation of the advanced electronic technology which
produced the popular C-30 and CM-30 controllers - standards of the solar
industry since 1975, with hundreds of thousands of units installed worldwide.
With an adjustable high limit of 50º-104ºF, the GL-30 is capable of handling
most differential temperature control functions for operation of domestic water
heating and sophisticated space heating and cooling. The GL-30 is designed to
control recirculation, drain-back and closed loop systems.
Replacement unit for CM30 and C30: • Control does not include power cord or sensors [must be
purchased separately or in a package] • Two
SB-10K sensors may be required. [sold separately] NOTE: TD-GL & DIX-30 Temperature Displays are discontinued
LED Indicators Three highly visible LEDs
show: • Power to control • Power out from
control • Power out from control due to a
recirculation mode to protect • the system from
freeze damage.
GL-30 Output The GL-30 output is rated
at 20 Amps and is designed to directly operate a pump or fan for heat
collection when the controller is sensing an appropriate temperature
differential.
Differential The GL-30 has an
adjustable differential with a range of 8º to 24ºF. Solar systems with long
pipe runs normally require a higher turn-on differential temperature, and
open loop systems with short pipe runs usually require a lower turn-on
differential temperature for optimum performance. The GL-30 offers versatility
to tailor controls to numerous specific systems designs.
Storage
High Limit The GL-30 allows you to set a high limit storage
temperature from 110º to 230ºF.
Recirculation Freeze
Protection Recirculation freeze protection, when enabled, turns the
GL-30 output on to circulate warmer storage water through the collectors
when near freezing temperatures are reached at the collector
sensor.
System Test Switch The system test switch
manually switches the GL-30 to ON, AUTO, or OFF for complete control over
the system at all times.
Product Application: Solar
Domestic Water Heating
System
_______________________________________________________
HELP » Contact Customer
Support • Toll-Free help
line offering product info and ordering support • Online e-mail technical and
installation support _______________________________________________________
A
complete typical solar domestic water heating system components and layout
is shown below.
Product Features: •
Differential temperature control •
8-20ºF adjustable turn-on differential •
4ºF fixed turn-off differential •
110-230ºF adjustable high limit •
120/240 VAC input • 20A, 2HP output
Product Specifications: •
Input power: 120 VAC or 240 VAC •
Output: SPDT powered contacts 1HP@115VAC,
2HP@240VAC •
rating @ 240VAC: 20A on NO contacts ; 10A on NC contacts •
Differential: 8/4 to 24/4°F •
High Limit: 110° to 230° F •
Environment: 15° to 130° F; 0 to 95% rH •
Accuracy: +/- 1°F •
Dimensions: 5.875" x 4.875" x 2.375" •
Temperature Sensors: Thermistor 10k @ 25°C/77°F not
included
Inside
view of the circuit
board
Product
Installation: View the following manual for installation and
troubleshooting
Download » Product
Installation Manual Download
» Goldline
Warranty
General
Control and Sensor Trouble-Shooting Tips:
All of the GoldLine
(formally Independent Energy) controls (including C30, CM30, G30 and GL30
series) and some of the Heliotrope General (HG) DTT series controls incorporated
the use of 10k sensors. Some of the earlier HG controls and some other
lesser known brands used 3k sensors.
To determine the type of sensor, the
resistance must be measured in ohms (using a volt/ohm meter) when the sensor is
at 77 degrees F. 10k measures 10,000 ohms and 3k measures 3,000 ohms. As
the temperature goes up, the resistance goes down.
Resistance can
be checked at any temperature, and then convert the ohm reading measured to
the temperature equivalent by using the conversion
chart.
Sensors can be purchased at Water Heaters Parts and
Supplies
Product
Manufacturer: Goldline Controls Inc.
Product Warranty:
10 Year Limited Warranty Goldline Controls Inc. now offers a full 10
year limited warranty on all solar controls and accessories! This
warranty will cover repair or replacement of the control at no cost
for the first 24 months. For years 3 through 5, the repair/ replacement
fee will be a maximum of 25% of the current list price, and for years 6
through 10, the repair/replacement fee will be a maximum of 50% of the
current list price. The best controls now have the best warranty. See the
Goldline warranty statement for
detail.
_______________________________________________________
Processing and Delivery Information: Please allow Processing
Time as stated above for your order, plus standard transportation delivery
time. Orders placed after 2PM EST may not begin processing until the next
business day. Please call for Rush Processing and/or Rush Shipping
options.
|