Home
»
Shop
»
Water Heaters
»
Solar Hot Water
»
Active Solar
»
Valves
»
VT2322G13B020
LogIn
|
CheckOut
Categories
Solar PV Electric
Water Heaters
Space Heating
Pool Heaters
Pool and Spa
Lighting
Water Conservation
Wind Power
Energy Savings
Outdoor Lifestyle
Preparedness
Gadgets
Parts & Supplies
Great Gift Ideas!
Clearance and Sales
New Arrivals
Information
LIVE SUPPORT
9am - 5pm EST M-F
800 333 9276
941 360 9276
Sales Support
Tech Support
Contact Info
Legal | Policies
Mailing List
Name:
Email Address:
Add:
Remove:
Manufacturers
Please Select
1
ACT, Inc. Metlu..
Air Energy Heat..
Alternate Energ..
Ameresco, Inc.
American Energy..
American SPS
American Water ..
AquaCal
AquaStar Pool P..
AquaTherm Pool ..
Attic Breeze, L..
AutoPilot Syste..
Avlite Systems
BP
BrassCraft Manu..
Cash Acme
Chromagen
Classy Caps Mfg..
Coleman Cable I..
Conbraco Indust..
Concorde Batter..
Current Cost, L..
Days Corporatio..
Earth Care Prod..
Eaton
Energy Laborato..
Enphase Energy
Erie
Eton corp.
Evergreen
EVnetics
Fafco - Clone
Feherguard
Flexible Soluti..
Floatron, Inc
FloControl
Gama Sonic
Goldline Contro..
GoSun Stove
Grundfos
Hanwha SolarOne
Hayward Industr..
Hefco Plastics,..
Heliodyne
Heliotrope Pool
Heliotrope Ther..
Honeywell
Horizon Venture..
HTP Inc
Hyundai
IMC Instruments..
Invensys Applia..
Ivan Labs
Jacques Giordan..
Jandy
JED Engineering
Keeton Industri..
King Technology
Laing Thermotec..
LED Grow World
Legend Valve
LG Electronics
Lochinvar
LuminAID
Mainline
Maxsa Innovatio..
MidWest Canvas
Morning Star Co..
MPowerd Inc.
Natural Current..
Niagra Industri..
Odyssey
Ogontz Corporat..
Out Back Power ..
P3 Internationa..
PCM Precision, ..
Pentair
Philips
Pool Heating Di..
Power Up
Power-One Inc.
Power-Save Ener..
PowerFilm Incor..
Primus Wind Pow..
ProSun Internat..
Raypak
Redring Electri..
Rheem
Rocky Reels
Rostra Vernathe..
Ruud
S-5!
Samlex America
Schneider Elect..
Sealite Pty Ltd
Seisco
Sentinel Power ..
Sharp
Shell
SMA America, In..
Sol Inc.
Solar Coil LLC
Solar Direct
Solar Panels Pl..
SolarEdge Techn..
Solartech Power..
SolarWorld
Solene, LLC
Southwest Windp..
Southwest Windp..
Sparco
Spears
Specialty Conce..
Spin-X Corporat..
Sta-Rite
Staber Industri..
Steca GmbH
Sun BD Corporat..
Sun Earth
Sun Frost
Sun Ovens Inter..
Sun Pumps
Suniva
SunModo Corp
SunRise Solar I..
Sunspool Corp
Suntech Power, ..
SunWize Technol..
Taco, Inc
Takagi Industri..
Techno-Solis
test1234<script..
Thermal Convers..
Thin-Lite Corp.
Tremont Electri..
TrendSetter Ind..
Tubular Skyligh..
UMA Solar
United States T..
Valley Forge Fl..
Vestergaard Fra..
Wagan Corp.
Watts
Wood Industries..
Xantrex
Yingli Green En..
Your Solar Home..
Zodiac Pool Sys..
Currencies
US Dollar
Credit Card Processing
© 2022 Solar Direct
All Rights Reserved
VT2322G13B020 Erie Motorized Check Valve 3/4 inch Threaded NPT Fitting
Model: VT2322G13B020
CLICK dropdown arrow in selection boxes to
configure product and determine total cost.
Base Price: $167.86
Shipping based on delivery destination:
Please Select an Option
Standard UPS-FedEx-USPS Contiguous US - Add (+$10.00)
Customer Pickup Sarasota Florida Only - Call for Availability
For Shipments Outside of the Contiguous US please
Contact Us
for a Quote
Optional Installation Services
Tell Someone About
This
Great Deal!
Found a lower price?
Let us know!
[?]
Processing:
1-2 Business Days
Plus Transportation Time
Motorized Check Valve
3/4 inch Threaded NPT Fitting
Model
VT2322G13B020
Erie Check Valve 120 Vac
Size
3/4 inch
Material
Body: Forged Brass
Seat: Brass
Stem: Nickel plated Brass
Paddle: Highly saturated nitrile [VS], Buna n [VT]
Fluid Temp.
32 to 200 ºF @ 104 Ambient ºF [0-93 ºC @ 40 ºC]
Maximum
Static
Pressure
300 psi [20.6 bar]
Seat Leakage
ANSI IV
Cv [Kvs]
2.5 [2.2]
Close Off
Pressure psi
[kPa]
40 [275]
Normally Open/
Normally Closed
NC
Product Applications:
PopTop Series valve bodies and actuators provide easy installation for a variety of heating and cooling applications. Valve’s actuator can be installed after valve body has been installed onto fan coil, baseboard, plumbing or air handler. VS Series valves are available for low pressure steam applications.
Product Function:
Ideal for active solar systems to prevent thermosyphoning [backflow], prevents heat loss at night.
A solar panel re-radiates heat on clear cold nights back into the sky. This phenomenon, known as thermosyphoning, causes the water in the solar panel to cool and fall due to the laws of physics. The hot water from the storage tank then begins to rise to displace the water in the panel. This cycle continues naturally without any mechanical input from the pump. If this process is not stopped, the temperature of the storage tank can drop dramatically overnight, sometimes resulting in a loss of 50 degrees or more.
To prevent thermosyphoning, a check valve must be used in the return line from the panel back to the storage tank. A mechanical check valve [spring or swing] can be used; however, they are highly prone to corrosion from poor quality water, and can easily stick open – defeating their purpose. The best solution is to use a motorized positive seal valve. Both Erie and Honeywell Motorized Check Valves provide excellent service life with a high quality product.
Product Features:
•
Direct replacement for all existing PopTop applications.
•
Hysteresis synchronous motor for long life
•
Spring return operation provides a fail-safe
•
Valve body rated for 300 psi static pressure
•
Available in a variety of voltages [110 volt standard]
•
Actuator mounts directly onto valve body without need for
•
linkages or calibration
•
Manual override lever [normally closed only]
•
Actuator can be replaced without any tools, or removal of valve
•
from system
•
VS Series available for low pressure steam
Product Specifications:
Erie Valve Model VT2322G13B020
[PDF format]
VIEW »
General Instructions
[PDF Format]
__________________________________________________________
Mounting
The valve can be mounted in horizontal or vertical piping. When installed in horizontal piping, the actuator must be above the valve body. When installed in horizontal piping the actuator can be tilted left or right but it must not be tilted below 85° from vertical.
__________________________________________________________
__________________________________________________________
HELP »
Contact Customer Support
•
Toll-Free help line offering product info and ordering support
•
Online e-mail technical and installation support
__________________________________________________________
PRODUCT INSTALLATION:
Inspection:
Inspect the package for damage. If package is damaged, notify the appropriate carrier immediately. If undamaged, open the package and inspect the device for obvious damage.
Return damaged products.
Requirements:
•
Tools [not provided]
•
Wrench 1 to 1-5/8" [if threaded valve]
•
Soldering equipment [if sweat fit] or flare
•
Other accessories as appropriate
Precautions:
•
Electrical shock hazard! Disconnect power before installation to
•
prevent electrical shock or equipment damage.
•
Make all connections in accordance with the electrical wiring
•
diagram and in accordance with national and local electrical
•
codes. Use copper conductors only.
•
All conductors shall be provided with insulation rated for the
•
highest voltage motor and end switch circuits.
•
Avoid locations where excessive moisture, corrosive fumes,
•
explosive vapors, or vibration are present.
•
Avoid electrical noise interference. Do not install near large
•
conductors, electrical machinery, or welding equipment.
•
When making lead connections within the actuator, use caution
•
not to put leads or connectors below the motor.
Note »
•
make certain there is no overhead water source that may drip
•
onto valve actuator.
•
In normal service, some condensation may occur on or around
•
the valve. A drip pan may be necessary or the valve body may
•
be insulated.
Piping
These valves must be piped so the paddle closes against the direction of flow. Flow is from B to A. When installing the actuator to a normally closed valve, the actuator must be placed in the manually open position by using the manual operating lever. The first time the valve is operated electrically, the manual operating lever of the actuator will transfer to the automatic position. The manual operating lever can be used to allow flushing of the system after installation. The valves are designed for application in closed hydronic heating and cooling systems. High levels of dissolved oxygen and chlorine found in open systems may attack the valve materials and result in premature failure. Install over a drip pan if condensation in chilled water applications occurs.
Note »
•
Three-way valves always require a normally closed actuator.
•
Three-way valves are always closed at the B port when
•
no power is applied to the motor.
•
On power-up the valve closes to A port on three-way valves.
•
Orient the three-way valve body as needed for normally open or
•
normally closed flow through coil.
Sweat Connections:
Do not solder with actuator in place, or with paddle against seat, as the heat can damage the unit. Before soldering, move the manual open lever into Open position then remove the actuator from the body. Orient paddle so it is not against a seat.
Use lead or tin based solder with melting point below 600 °F. Do not overheat. Direct flame tip away from valve. Cool valve quickly with a wet cloth.
Body assembly can be submerged for leak testing prior to attaching the actuator.
CHECK OUT:
•
Make sure the valve stem rotates freely before and after
•
installing the actuator.
•
If the stem does not operate freely it may indicate that the stem
•
was damaged and may require that the valve be repaired
•
or replaced.
•
After the piping is under pressure, check the valve body and
•
the connections for leaks.
•
After the valve and actuator are installed, power the actuator
•
and check the operation.
THEORY OF OPERATION:
PopTop Series are two position spring return valves. When powered, the actuator moves to the desired position, tensing the spring return system. When power is removed the actuator returns to the normal position.
PopTop Series two position spring return valves can be purchased with an optional built-in auxiliary SPDT end switch for interfacing or signaling; for example, zone pump burner control.
PRODUCT MAINTENANCE:
PopTop Series two position spring return valves are maintenance free. Replace defective modules. Actuator may be replaced without removing the valve.
Regular maintenance of the total system is recommended to assure sustained, optimum performance.
FIELD REPAIR:
Replace any damaged or failed components with complete replacement unit.
_______________________________________________________
A typical solar domestic water heating system components and layout
is shown below.
_______________________________________________________
Product Manufacturer:
Schneider Electric (Previously Invensys Building Systems, Inc.)
Delivery Information:
Please allow 3 to 5 business days for
orders to be processed, plus standard transportation delivery time.
Customers who bought this product also purchased
Grundfos Hot Water Circulating Pump - Stainless Steel Body, 115V, GU 125 Union Mount
S-5! Non-Penetrating Snap-Together Metal Roof Seam Clamp - Model S-5-S
AM101-1LF Sparco Lead-Free, Anti-Scald, Anti-Chill, Mixing Valve 3/4" FptxFptxFpt
VORTEX 4x12 Solar
Pool Heating Panels
Panels Only
Goldline GL-30-LCO Solar Control Package with Power Cord and Sensors
Heliodyne Solar Recirculation Sensor Model: SAS-10
Quick Search
Enter keywords
Advanced Search
View all Products
View Cart
0 items
Manufacturer Info
-
Other products
Invest in Solar
Promote Solar
Installations
Professional installation available for most products.
Call us today for custom orders & installation quotes.
Solar Affiliates
Affiliate Log In
Solar Affiliate Program
Great Deals
Tell A Friend
Tell someone you know about this product.
Connect with Us
Facebook
Twitter