Where the World Shops for Energy
  Home » Shop » Water Heaters » Solar Hot Water » Active Solar » Valves » FP35-SE-2 LogIn  |  CheckOut   
Categories
Solar PV Electric
Water Heaters
Space Heating
Pool Heaters
Pool and Spa
Lighting
Water Conservation
Wind Power
Energy Savings
Outdoor Lifestyle
Preparedness
Gadgets
Parts & Supplies
Great Gift Ideas!
Clearance and Sales
New Arrivals
Information
LIVE SUPPORT
9am - 5pm EST M-F
800 333 9276
941 360 9276
Sales Support
Tech Support
Contact Info
Legal | Policies
Mailing List
Name:

Email Address:

Add:
Remove:
Manufacturers
Currencies

Solar Direct, Inc. is a BBB Accredited Business. Click for the BBB Business 
Review of this Solar Energy Equipment & Systems Dealers in Sarasota FL
Credit Card Processing


 © 2022 Solar Direct
 All Rights Reserved
FP35-SE-2 Invensys/Eaton/Dole Lead-Free Freeze Protection Valve *Out of Stock*
   Model: FP35-SE-2
FP35-SE-2 Invensys/Eaton/Dole Lead-Free Freeze Protection Valve *Out of Stock*
CLICK dropdown arrow in selection boxes to
    configure product and determine total cost.

Base Price:  $94.68
    Quantity Discount:
     
    Shipping based on delivery destination:
     
        For Shipments Outside of the Contiguous US please Contact Us for a Quote
            Optional Installation Services
            Tell Someone About This Great Deal!
            Found a lower price? Let us know![?]
This Item Is Currently Out Of Stock
Processing: 1-2 Business Days
Plus Transportation Time



    See new Freeze protection Valve with improved features: here 

    invensys valveInvensys/Eaton/Dole 
    Lead-Free Freeze Protection Valve
    Model FP35-SE-2

    Valve opening up to 38 degrees

    WARNING: See critical warning below relating to proper selection of valve model related to application.

    The Invensys FP Freeze Protection Valves utilize a reliable self-contained Dole Power Element which is sensitive to temperature and operates without any electrical power or sensors. Typically in solar applications, the valve port opens on descending temperatures allowing the near freezing water in the solar panel to be discharged and replaced with warmer supply water. When the warmer water reaches the valve, the port closes and water discharge stops.

    This cycle will repeat as often as necessary to help prevent freezing. The amount of water dispensed depends mainly on ambient air temperature, make up water temperature, the duration of the cold spell and the number and size of collectors. The system is functioning properly when water is being discharged from the valve during near freezing conditions. For water to be discharged at the time of operation, system water pressure must be maintained.

    Product Application: Solar Domestic Water Heating System

    Product Function:
    Protects solar collectors and exposed piping from freezing

    Product Features:
    Easily installed on existing systems
    150 PSI maximum operating pressure
    Corrosion resistant design
    FDA and NSF listed materials
    LA testing and IAPMO listed
    Anti-siphon and alternate discharge port
    Discharge port for 1/4" plastic pipe or 5/8" ID hose
    1/2" brass male pipe thread inlet port for positive seal
    Tamper resistant design
    Nominal start to open temperature is 38 ºF
    Completely mechanical operating principle
    High temperature UV stabilized body material
    Ideal for backup freeze protection
    1-Year Limited Factory Warranty - see warranty details below


    freeze valve diagram

    freeze valve diagram

    _______________________________________________________

    HELP » Contact Customer Support
    Toll-Free help line offering product info and ordering support
    Online e-mail technical and installation support
    _______________________________________________________

    A typical solar domestic water heating system components and layout is shown below.




    Freeze Protection Valve Application Considerations:

    1. The Invensys "Freeze Protection Valve(s)" functions properly
    provided the valve is installed in a location, where during operation, the warmer supply water first passes through the collectors and/or pipe to be protected and then through the valve. The "Freeze Protection Valve(s)" should be located in a position to allow good water distribution through the solar panel
    so that when the valve opens, water flows as evenly as possible through all the collector tubes. Location of the valve may vary depending on the system design and piping.

    2. IMPORTANT INSTALLATION NOTES: Select a mounting position where the valve will sense the coldest anticipated ambient temperature. When used in conjunction with active systems, the valve should also be located within close proximity of the collector outlet with 2"-6" offset below the collector header (see illustration). Do not mount in a position where the valve will be exposed to an unnatural heat source (i.e. poorly insulated roof, dryer or furnace vents, etc). The plumbing from the collector outlet to the point where it penetrates the roof should be insulated (this will prevent heat loss, and protect the piping from freeze damage in cold temperatures).  The Freeze Protection Valve must be connected to the main return line from a tee fitting and have 8”-10” of copper piping between the tee and the valve – this section of pipe must NOT be insulated, and must be painted black to properly simulate the collector sensing outside temperature conditions.  This section of pipe should be no less than 1/2” diameter, and preferably be 3/4” diameter (even if the main return line is only 1/2” diameter) to provide maximum surface area to sense outside temperature conditions.  This section of pipe must be 1”-2” below the outlet pipe to prevent exposure to high temperatures that can develop near the collector outlet (see illustration).

    3. The system must be subjected to normal operating pressures of
    between 20 and 125 PSI at all times for the valve to operate properly. Do not shut off water supply to the collectors or isolate the collectors from the city water supply.

    4. When a check valves is required in the return line, be sure it is operating and installed in a proper location with respect to the Freeze Protection Valve. Water flow must be prevented from “bypassing” the collector. If the check valve leaks internally and does not properly seat, water flow may be bypassed through the check valve rather than through the collector.

    5. Do not insulate the Freeze Protection Valve or exposed pipe between the collector return line and the Freeze Protection Valve. Any other section of exposed pipe where no water flow exists during valve operation should be heavily insulated.

    6. Install by applying torque with a wrench to the square metal inlet flange. Do not apply torque to the plastic body.

    7. For proper utilization of the anti-siphon port, the Freeze Protection Valve should be installed in a vertical position with discharge port down.  To prevent wasps or other insects from nesting inside the discharge port which could cause blockage of water flow, wire or plastic screen (not included) can be placed over the openings and secured.  Be sure that the screen will not interfere with discharging water.

    8. To enhance customer satisfaction of this product, we recommend a plastic discharge tube be connected to the 1/4" pipe threads or the 5/8" barbs, then routed to a safe, nonobjectionable location where the discharged water will drain.

    9. If a discharge tube is used, make sure it will drain freely and is installed in accordance to local codes. Avoid water traps in the discharge tube that could freeze and prevent drainage. The valve has an alternate path for discharge water flow should the discharge tube become impaired.

    10. Do not attempt to disassemble the top cover. The inlet retention flange can be removed to inspect the screen for periodic cleaning and replacement.
    _______________________________________________________

    Product Manufacturer: Invensys Appliance Controls.

    Manufacturer Warranty:
    Dole/Invensys Energy Control Products are warranted by the manufacturer to be free from defects in material and workmanship for a period of one year from the date of installation, when properly installed and used in accordance with the installation instructions.

    Invensys obligation is limited to the repair or exchange of the defective parts and does not include reimbursement for any removal or installation expenses.

    To make a claim under this warranty please contact Solar Direct for return instructions. This warranty is in lieu of all warranties expressed or implied, including warranties of merchantability and fitness for a particular purchase.

    NOTE: During cold weather, it is normal for the valve to dispense water from its discharge port even when ambient air temperatures are several degrees above freezing.

    _______________________________________________________

    WARNING: Solar collectors can reach internal temperatures up to 10 degrees below the outside ambient air temperature. Standard Active Open Loop Solar Systems typically require a model FP45 valve to ensure proper protection. Passive Batch or Integrated Collector Storage (ICS) systems such as the ProgressivTube have a much larger volume and mass of stored water, and will not freeze as quickly as a Active Open Loop Solar System, therefore they can typically utilize a model FP35 valve. This condition results from a phenomenon known as “night-sky emissivity”. The emissivity of a material is the ratio of energy radiated by the material (solar panel) to energy radiated (or absorbed) by a black body (the sky); it is a measure of a material's ability to absorb and radiate energy. Since solar collectors are coated with a black surface they are very good at conducting and emitting energy. When the outside temperature approaches freezing, the surface of the solar collector begins to emit energy to the night sky. When the atmosphere is clear with no clouds, the transfer of energy is accelerated. In layman terms, this means that on a cold clear night, the water in the solar panel can be up to 10 degrees colder than the outside temperature. A Freeze Protection Valve needs to begin opening when the outside temperature drops to 42 degrees and below. As the temperature drops from 42 to 32 the volume of water discharged from the valve increases. Consult the owner’s manual of your collector and/or system to determine the correct valve model to use; Solar Direct and/or The Energy Supermarket makes no claim as to the correct valve to use, and/or its usage and application; and assumes no liability for damages resulting from correct or incorrect use of this product.

    Processing and Delivery Information: Please allow Processing Time as stated above for your order, plus standard transportation delivery time. Orders placed after 2PM EST may not begin processing until the next business day. Please call for Rush Processing and/or Rush Shipping options.

Reviews This Item Is Currently Out Of Stock

Customers who bought this product also purchased
SunEarth Active Solar Water Heater Panel w/Mounting Hardware, One 4 x 8 Collector
SunEarth Active Solar Water Heater Panel w/Mounting Hardware, One 4 x 8 Collector
107-327NL T-206 Legend Boiler Drain Valve 1/2 Inch
107-327NL T-206 Legend Boiler Drain Valve 1/2 Inch
V4043A1010/U Honeywell Motorized Zone Check Valve Sweat N.C.
V4043A1010/U Honeywell Motorized Zone Check Valve Sweat N.C.
Heliodyne Solar Recirculation Sensor Model: SAS-10
Heliodyne Solar Recirculation Sensor Model: SAS-10
LF111-125 Watts Pressure Relief Valve 125 Psi. Lead Free<br>
LF111-125 Watts Pressure Relief Valve 125 Psi. Lead Free
Heliocol CPVC Pipe Connector - Model HC-117
Heliocol CPVC Pipe Connector - Model HC-117
Quick Search
Enter keywords

• Advanced Search
View all Products
View Cart more
0 items
Manufacturer Info
Other products
Invest in Solar
Promote Solar
Installations more
Professional installation available for most products.
Call us today for custom orders & installation quotes.
Solar Affiliates
Solar Affiliate Program

Affiliate Log In
Solar Affiliate Program
Great Deals
T-Shirts
Tell A Friend
 
Tell someone you know about this product.
Connect with Us
      follow us 
on facebook Facebook
      follow us on twitter Twitter
      

12