Where the World Shops for Energy
  Home » Shop » Parts & Supplies » Water Heaters » Solar Hot Water » Active Solar » Valves » VT2322G13B020 LogIn  |  CheckOut   
Categories
Solar PV Electric
Water Heaters
Space Heating
Pool Heaters
Pool and Spa
Lighting
Water Conservation
Wind Power
Energy Savings
Outdoor Lifestyle
Preparedness
Gadgets
Parts & Supplies
  Pool and Spa
  Water Heaters
    Solar Hot Water
      Active Solar
        Controls & Sensors
        Pumps
        Valves
        Collectors
        Tanks
        Plumbing
        Mounting
        Closed Loop
        Heat Transfer
      Passive Solar
      Solar Showers
    Tankless Heater
    Instant Heat
  Solar PV Electric
  Wind Power
  Space Heating
Great Gift Ideas!
Clearance and Sales
New Arrivals
Information
LIVE SUPPORT
9am - 5pm EST M-F
800 333 9276
941 360 9276
Sales Support
Tech Support
Contact Info
Legal | Policies
Mailing List
Name:

Email Address:

Add:
Remove:
Manufacturers
Currencies

Solar Direct, Inc. is a BBB Accredited Business. Click for the BBB Business 
Review of this Solar Energy Equipment & Systems Dealers in Sarasota FL
Credit Card Processing


 © 2022 Solar Direct
 All Rights Reserved
VT2322G13B020 Erie Motorized Check Valve 3/4 inch Threaded NPT Fitting
   Model: VT2322G13B020
VT2322G13B020 Erie Motorized Check Valve 3/4 inch Threaded NPT Fitting
CLICK dropdown arrow in selection boxes to
    configure product and determine total cost.

Base Price:  $167.86
    Shipping based on delivery destination:
     
        For Shipments Outside of the Contiguous US please Contact Us for a Quote
            Optional Installation Services
            Tell Someone About This Great Deal!
            Found a lower price? Let us know![?]
In Cart
Processing: 1-2 Business Days
Plus Transportation Time



    Motorized Check Valve
    3/4 inch Threaded NPT Fitting
    Model
    VT2322G13B020

    Erie Check Valve  120 Vac
    Size  3/4 inch
    Material Body: Forged Brass
    Seat: Brass
    Stem: Nickel plated Brass
    Paddle: Highly saturated nitrile [VS], Buna n [VT]
    Fluid Temp. 32 to 200 ºF @ 104 Ambient ºF [0-93 ºC @ 40 ºC]
    Maximum
    Static
    Pressure
     300 psi [20.6 bar] 
    Seat Leakage ANSI IV 
    Cv [Kvs] 2.5 [2.2]
    Close Off
    Pressure psi
    [kPa]
    40 [275]
    Normally Open/
    Normally Closed
    NC

    Product Applications:
    PopTop Series valve bodies and actuators provide easy installation for a variety of heating and cooling applications. Valve’s actuator can be installed after valve body has been installed onto fan coil, baseboard, plumbing or air handler. VS Series valves are available for low pressure steam applications.

    Product Function:
    Ideal for active solar systems to prevent thermosyphoning [backflow], prevents heat loss at night.

    A solar panel re-radiates heat on clear cold nights back into the sky.  This phenomenon, known as thermosyphoning, causes the water in the solar panel to cool and fall due to the laws of physics.  The hot water from the storage tank then begins to rise to displace the water in the panel.  This cycle continues naturally without any mechanical input from the pump.  If this process is not stopped, the temperature of the storage tank can drop dramatically overnight, sometimes resulting in a loss of 50 degrees or more.

    To prevent thermosyphoning, a check valve must be used in the return line from the panel back to the storage tank.  A mechanical check valve [spring or swing] can be used; however, they are highly prone to corrosion from poor quality water, and can easily stick open – defeating their purpose.  The best solution is to use a motorized positive seal valve.  Both Erie and Honeywell Motorized Check Valves provide excellent service life with a high quality product.

    Product Features:
    Direct replacement for all existing PopTop applications.
    Hysteresis synchronous motor for long life
    Spring return operation provides a fail-safe
    Valve body rated for 300 psi static pressure
    Available in a variety of voltages [110 volt standard]
    Actuator mounts directly onto valve body without need for
    linkages or calibration
    Manual override lever [normally closed only]
    Actuator can be replaced without any tools, or removal of valve
    from system
    VS Series available for low pressure steam

    Product Specifications:
    Erie Valve Model VT2322G13B020 [PDF format]
    VIEW » General Instructions [PDF Format]

    __________________________________________________________

    erie valve diagram

    Mounting
    The valve can be mounted in horizontal or vertical piping. When installed in horizontal piping, the actuator must be above the valve body. When installed in horizontal piping the actuator can be tilted left or right but it must not be tilted below 85° from vertical.
    __________________________________________________________





    __________________________________________________________

    HELP » Contact Customer Support
    Toll-Free help line offering product info and ordering support
    Online e-mail technical and installation support
    __________________________________________________________


    PRODUCT INSTALLATION:

    Inspection:
    Inspect the package for damage. If package is damaged, notify the appropriate carrier immediately. If undamaged, open the package and inspect the device for obvious damage.
    Return damaged products.

    Requirements:
    Tools [not provided]
    Wrench 1 to 1-5/8" [if threaded valve]
    Soldering equipment [if sweat fit] or flare
    Other accessories as appropriate

    Precautions:
    Electrical shock hazard! Disconnect power before installation to
    prevent electrical shock or equipment damage.
    Make all connections in accordance with the electrical wiring
    diagram and in accordance with national and local electrical
    codes. Use copper conductors only.
    All conductors shall be provided with insulation rated for the
    highest voltage motor and end switch circuits.
    Avoid locations where excessive moisture, corrosive fumes,
    explosive vapors, or vibration are present.
    Avoid electrical noise interference. Do not install near large
    conductors, electrical machinery, or welding equipment.
    When making lead connections within the actuator, use caution
    not to put leads or connectors below the motor.

    Note »

    make certain there is no overhead water source that may drip
    onto valve actuator.
    In normal service, some condensation may occur on or around
    the valve. A drip pan may be necessary or the valve body may
    be insulated.

    Piping
    These valves must be piped so the paddle closes against the direction of flow. Flow is from B to A. When installing the actuator to a normally closed valve, the actuator must be placed in the manually open position by using the manual operating lever. The first time the valve is operated electrically, the manual operating lever of the actuator will transfer to the automatic position. The manual operating lever can be used to allow flushing of the system after installation. The valves are designed for application in closed hydronic heating and cooling systems. High levels of dissolved oxygen and chlorine found in open systems may attack the valve materials and result in premature failure. Install over a drip pan if condensation in chilled water applications occurs.

    Note »
    Three-way valves always require a normally closed actuator.
    Three-way valves are always closed at the B port when
    no power is applied to the motor.
    On power-up the valve closes to A port on three-way valves.
    Orient the three-way valve body as needed for normally open or
    normally closed flow through coil.

    Sweat Connections:
    Do not solder with actuator in place, or with paddle against seat, as the heat can damage the unit. Before soldering, move the manual open lever into Open position then remove the actuator from the body. Orient paddle so it is not against a seat.
    Use lead or tin based solder with melting point below 600 °F. Do not overheat. Direct flame tip away from valve. Cool valve quickly with a wet cloth.
    Body assembly can be submerged for leak testing prior to attaching the actuator.

    CHECK OUT:
    Make sure the valve stem rotates freely before and after
    installing the actuator.
    If the stem does not operate freely it may indicate that the stem
    was damaged and may require that the valve be repaired
    or replaced.
     After the piping is under pressure, check the valve body and
    the connections for leaks.
     After the valve and actuator are installed, power the actuator
    and check the operation.

    THEORY OF OPERATION:
    PopTop Series are two position spring return valves. When powered, the actuator moves to the desired position, tensing the spring return system. When power is removed the actuator returns to the normal position.
    PopTop Series two position spring return valves can be purchased with an optional built-in auxiliary SPDT end switch for interfacing or signaling; for example, zone pump burner control.

    PRODUCT MAINTENANCE:
    PopTop Series two position spring return valves are maintenance free. Replace defective modules. Actuator may be replaced without removing the valve.

    Regular maintenance of the total system is recommended to assure sustained, optimum performance.

    FIELD REPAIR:
    Replace any damaged or failed components with complete replacement unit.


    _______________________________________________________

    A typical solar domestic water heating system components and layout
    is shown below.



    _______________________________________________________

    Product Manufacturer: Schneider Electric (Previously Invensys Building Systems, Inc.)

    Delivery Information: Please allow 3 to 5 business days for
    orders to be processed, plus standard transportation delivery time.

Reviews In Cart

Customers who bought this product also purchased
Goldline GL-30-LCO Solar Control Package with Power Cord and Sensors
Goldline GL-30-LCO Solar Control Package with Power Cord and Sensors
VORTEX 4x12 Solar<br>Pool Heating Panels<br>Panels Only
VORTEX 4x12 Solar
Pool Heating Panels
Panels Only
Heliodyne Solar Recirculation Sensor Model: SAS-10
Heliodyne Solar Recirculation Sensor Model: SAS-10
Quick Search
Enter keywords

• Advanced Search
View all Products
View Cart more
0 items
Manufacturer Info
Other products
Invest in Solar
Promote Solar
Installations more
Professional installation available for most products.
Call us today for custom orders & installation quotes.
Solar Affiliates
Solar Affiliate Program

Affiliate Log In
Solar Affiliate Program
Great Deals
T-Shirts
Tell A Friend
 
Tell someone you know about this product.
Connect with Us
      follow us 
on facebook Facebook
      follow us on twitter Twitter
      

Energy savings products at Factory Direct Prices!