Where the World Shops for Energy
  Home » Shop » Parts & Supplies » Water Heaters » Solar Hot Water » Active Solar » Valves » LF70A-F-075 LogIn  |  CheckOut   
Categories
Solar PV Electric
Water Heaters
Space Heating
Pool Heaters
Pool and Spa
Lighting
Water Conservation
Wind Power
Energy Savings
Outdoor Lifestyle
Preparedness
Gadgets
Parts & Supplies
  Pool and Spa
  Water Heaters
    Solar Hot Water
      Active Solar
        Controls & Sensors
        Pumps
        Valves
        Collectors
        Tanks
        Plumbing
        Mounting
        Closed Loop
        Heat Transfer
      Passive Solar
      Solar Showers
    Tankless Heater
    Instant Heat
  Solar PV Electric
  Wind Power
  Space Heating
Great Gift Ideas!
Clearance and Sales
New Arrivals
Information
LIVE SUPPORT
9am - 5pm EST M-F
800 333 9276
941 360 9276
Sales Support
Tech Support
Contact Info
Legal | Policies
Mailing List
Name:

Email Address:

Add:
Remove:
Manufacturers
Currencies

Solar Direct, Inc. is a BBB Accredited Business. Click for the BBB Business 
Review of this Solar Energy Equipment & Systems Dealers in Sarasota FL
Credit Card Processing


 © 2022 Solar Direct
 All Rights Reserved
LF70A-F-075 Watts Lead Free Mixing Valve. 3/4 Inch
   Model: LF70A-F-075
LF70A-F-075 Watts Lead Free Mixing Valve. 3/4 Inch
CLICK dropdown arrow in selection boxes to
    configure product and determine total cost.

Base Price:  $123.16
    Shipping based on delivery destination:
     
        For Shipments Outside of the Contiguous US please Contact Us for a Quote
    Size:
     
            Optional Installation Services
            Tell Someone About This Great Deal!
            Found a lower price? Let us know![?]
In Cart



    watts vavleWatts Mixing Valve
    LF70A-F-075 -  3/4 Inch

    Lead-Free

    70A Hot Water Extender Tempering Valve
    Series 70A Hot Water Extender Tempering Valves are used in residential water supply applications to mix cold and hot water to extend capacity of water heater storage tanks and hot water boiler tankless heaters. 

    You can meet various installation requirements with the Watts 70A Series Hot Water Extender Tempering Valves. They are available in 1⁄2" and 3⁄4" [15 - 20mm] sizes, with sweat connections. Temperature range 120° to 160°F [49°- 71°C].

    The hydraulically-operated thermostat opens a spring loaded check in the cold water inlet allowing cold water to mix with the hot water.

    Maintenance is very simple, as the thermostat is easily removed and replaceable as a unit. Valve bodies are of brass construction that is recognized and required to resist corrosive domestic hot water conditions.

    Product Application:
    Hot water extender tempering valves are used in residential water supply applications. Recommended for tankless heater, water heater and solar installations


    Product Function:
    Adjustable temperature
    control - mixes hot with cold
    water to preset temperature.

    Product Features:
    Brass valve bodies
    Simple maintenance
    thermostat assembly
    is easily removed and
    replaceable as a unit
    "FINGER TIP" Dial
    adjustment Cap
    Stainless steel spring
    with sweat connections



    Product Warranty:
    1-Year Limited Factory Warranty - see warranty details below 

    Maximum Pressure:
    150psi [10 bars]
    Series 70A temperature range: 120°F to 160°F

    _______________________________________________________

    watts materials and dimensions

    Watts 70A Mixing Valve Dimensions and Weight
    Dimensions
    Weight
    Size
    A
    B
    D
    *
    in.
    mm
    in.
    mm
    in.
    mm
    in.
    mm
    in.
    mm
    lbs.
    kg.
    1/2
    15
    2-1/32
    52
    3-11/16
    94
    2-3/16
    56
    15/16
    24
    3/4
    .3
    3/4
    20
    2-3/4
    69
    4-1/8
    105
    2-27/32
    72
    1-3/32
    28
    1-1/4
    .6
    _________________________________________________________ 

    HELP » Contact Customer Support
    Toll-Free help line offering product info and ordering support
    Online e-mail technical and installation support
    _________________________________________________________


    Installation Note:
    Valve should be installed by a licensed contractor

    Product Installation: 
    Close both hot & cold water shutoff valves upstream of the valve
    Bleed pressure from the system.
    Remove the thermostat and bonnet assembly [A], which is
    hand-tight, from body and install valve body as illustrated in
    diagram. Valve must be trapped as shown.
    Reinsert Thermostat and Bonnet assembly in body and tighten
    knurled portion of bonnet securely with pliers or channel locks.
    START UP REQUIREMENTS: Open cold water then hot water
     shutoff valves. The cold water supply line to Series 70A valve
    should always be opened first to prevent possible thermostat
    damage.

    HELP » Installation Manual[PDF Format]

    Caution:
    Periodic inspection by a licensed contractor is recommended. Corrosive water conditions, temperatures over 210°F [99°C], unauthorized adjustments or repair could render the valve ineffective for service intended. Regular checking and cleaning of thermostat assembly helps to assure maximum life and proper product function. Frequency of cleaning depends upon local water conditions.

    Watts 70A Series Troubleshooting Guide

    Problem

    Cause

    Solution

    Fluctuating or erratic hot water temperature at fixture. Heavy draws of either cold or hot water elsewhere in the system, such as clothes washer or dishwasher.


    Unbalanced pressures.
    Hot water temperature control valves cannot compensate for this condition. Check
    valves in hot and cold legs to hot water temperature control
    valve would help but not cure the problem.

    Install balancing or throttling valves (shutoff valves) in hot
    and cold legs to hot water extender tempering valve and
    adjust accordingly for demand.
    Hot water backing up into cold water line. Hot water pressure overriding cold pressure. Install check valve in cold water leg to hot water temperature
    control valve.
    Cannot adjust water temperature to desired temperature. Unequal pressures.

    Hot or cold temperature differential.

    Valve undersized.

    A balancing or throttling valve must be installed in the cold water leg to the hot water temperature control valve to throttle or restrict the pressure. In most installations, the cold water supply line feeds both the hot water temperature control valve and the water heater or tankless heater. To compensate for the pressure drop through the heater, the cold water to the hot water temperature control valve must be throttled or reduced.

    Check water heater controls to verify that the water temperature
    is the same as the heater thermostat setting.

    Check gpm flow required versus gpm flow capacity of valve.

    High pressure drop through hot water temperature control valve. Valve undersized. Install larger hot water temperature control valve.
    Insufficient hot water during peak demand
    Valve undersized.


    Heater or capacity insufficient for demand.
    Check gpm flow required during peak demand period and
    size hot water temperature control valve accordingly.
    Frequent failure of thermostatic element. Thermostatic element exposed to extremely high temperature.

    Corrosive water conditions. (Buildup of mineral deposits)

    Electrolysis (pitting deterioration, etc.)
    Check heater thermostat setting.
    Hot water temperature control valve must be trapped at least
    8" to 12" as per installation instructions. Install check valves
    as recommended.

    Frequent cleaning of thermostat element and plunger would
    tend to prolong the life of the element. A small coating of
    FDA approved silicone lubricant in the piston area of the
    element would also help.

    Electrically ground the piping system or install dielectric
    unions.
    All hot or cold water flows at hot fixture. This problem will require considerable troubleshooting
    met. Minimum flow requirement for 70A series valves is 2 gpm.
    Verify that complete installation instructions were followed:

    Is valve properly trapped?

    Check to see if thermostatic element has failed.

    Check to see if temperature control on water heater is
    set at desired temperature.

    Check to see if minimum flow requirements for valve
    size are met. Minimum flow requirements for 70A series valves is 2 gpm.


    WARNING
    Watts hot water extender tempering valves cannot used for tempering water temperature at fixtures. Severe bodily injury [i.e., scalding or chilling] and/or death may result depending upon system water pressure changes and/or supply water temperature changes. A.S.S.E. standard 1016 listed devices such as watts models L111 or MMV should used at fixtures to prevent possible injury.

    The WATTS hot water tempering valves are designed to be installed
    at or near the boiler or hot water heater. They are not designed to compensate for system pressure and/or temperature fluctuations and should not be used where devices tested to S.S.E. standard 1016 are required. These WATTS valves should never be used to provide "anti-scald" or "anti-chill" service.

    _______________________________________________________

    Product Manufacturer: Watts Industries Inc.

    Manufacturer Warranty:
    Watts Regulator Company warrants each product against defects in material and workmanship for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge. This shall constitute the exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental or consequential damages, including without limitation, damages or other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemicals, or any other circumstances over which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product. The company makes no other warranties express or implied except as provided in this limited warranty.
    _______________________________________________________

    Delivery Information: Please allow 3 to 5 business days for
    orders to be processed, plus standard transportation delivery time.

Reviews In Cart

Customers who bought this product also purchased
Goldline GL-30 Solar Control Unit
Goldline GL-30 Solar Control Unit
Pipe Flashing Kit - EPDM, for Solar Water Heater Systems, Model PFK-E-0.50/0.75
Pipe Flashing Kit - EPDM, for Solar Water Heater Systems, Model PFK-E-0.50/0.75
Mounting Kit - Fixed, Shingle/Metal Roof - for Solar Water Heater Systems, Model MK-CR-F-S/M
Mounting Kit - Fixed, Shingle/Metal Roof - for Solar Water Heater Systems, Model MK-CR-F-S/M
AET Mounting Kit - Fixed, Shingle/Metal Roof - for Solar Water Heater Systems, Model MK-AE-F-S/M
AET Mounting Kit - Fixed, Shingle/Metal Roof - for Solar Water Heater Systems, Model MK-AE-F-S/M
Steca/Solene Digital Solar Control Package includes line cord, outlet and two sensors
Steca/Solene Digital Solar Control Package includes line cord, outlet and two sensors
VT2212G13B020 Erie Motorized Zone Check Valve 1/2 inch fittings. Sweat Connections
VT2212G13B020 Erie Motorized Zone Check Valve 1/2 inch fittings. Sweat Connections
Quick Search
Enter keywords

• Advanced Search
View all Products
View Cart more
0 items
Manufacturer Info
Other products
Invest in Solar
Promote Solar
Installations more
Professional installation available for most products.
Call us today for custom orders & installation quotes.
Solar Affiliates
Solar Affiliate Program

Affiliate Log In
Solar Affiliate Program
Great Deals
T-Shirts
Tell A Friend
 
Tell someone you know about this product.
Connect with Us
      follow us 
on facebook Facebook
      follow us on twitter Twitter
      

12