SEISCO Tankless Electric Water Heater Model
RA-28-208, 208 Volt
The tankless water heater that others can only claim to be!
After 14
years of research and testing, the SEISCO, whose technology has earned its
developer 5 separate U.S. and many additional foreign patents, is recognized as
the STANDARD for all tankless water heaters.
The SEISCO tankless water
heater has earned International recognition for providing the highest level of
temperature control performance, reliability and safety in its operation over
any tankless water heater anywhere in the world today.
Application:
A four-chamber model
designed generally for domestic water heating in whole house and booster
applications.
Seisco RA-28-208
The RA-28 is the most popular
residential model for providing a continuous supply of hot water for as long as
you need it. Sized to replace a 50 gallon tank water heater, providing endless
hot water for most applications. Ideal companion to Solar and Geothermal passive
heat recovery systems. (Minimum 150 AMP Whole House Electrical Service
recommended)
This on-demand tankless water heater is a powerful
replacement for traditional tank-type heaters and is the enabling technology for
use as back-up to active renewable energy systems such as solar and geothermal
water heating systems. The temperature activated control works effectively in
re-circulating systems and in combination with tank-type heaters.
SEISCO Tankless Water Heater
Specifications 4 Chambers - Model RA-28 -208 |
MODEL |
RA-28-208 |
KW |
28 |
Elements |
7000 watts x 4 |
Btu/hr |
95560 |
Kg-cal/min |
400 |
TEMPERATURE
RISE |
95 ฐF @ 2.0 GPM |
76 ฐF @ 2.5 GPM |
64 ฐF @ 3.0 GPM |
48 ฐF @ 4.0 GPM |
50 ฐC @ 8 L/min |
40 ฐC @ 10 L/min |
33 ฐC @ 12 L/min |
25 ฐC @ 16 L/min |
MECHANICAL
|
Size HxWxD |
15x 15x 6 in 40x 40x
16 cm |
Plumbing fittings |
3/4-in NPT nipple x 2 |
Shipping weight |
23 lbs / 10.5 kg |
ELECTRICAL |
V |
208 |
A (max) |
116 |
Hz |
50 / 60 |
Circuits |
30A x
4 |
To see all models, please click here
Product Benefits:
Continuous and Endless
Supply of Hot Water
Space Savings
Safety and Health Benefits
Smart Technology
No Maintenance
Environmental Benefits
Product
Features:
UL 499 Approval Listing for Water Heating Applications
Works with tubing and manifold systems
No minimum flow activation required
Built-in DSM Utility Integration option
Compatible with Home Energy Management Systems
No moving parts
Very small &
compact
Light
weight modular construction
No restriction to flow
Standard 3/4 inch plumbing connections
Microprocessor digital
control
Power
sharing & variable power control technology
Continuous
venting
Heats
continuously only when needed, no storage
Self-diagnostics
Redundant safety devices
High performance polymer
nylon chamber material
Built-in Leak detector and alarm
Rust & corrosion resistant
Seisco Warranty
4
Chambers
The same advanced microprocessor technology and
thermoplastic construction are used in both 2
Chamber and 4 Chamber models, therefore, many of the parts are
interchangeable. There are no moving parts or flow restricting devices used in
Seisco heaters.
Flow/No Flow Detection
Seisco uses a unique flow/no
flow detection system utilizing temperature sensors for flow detection. In
standby, the heater maintains a very subtle temperature gradient and flow is
detected when there is a change in the gradient.
Microprocessor
Control
The advanced microprocessor control turns the power on
through a set of relays and turns the power off when flow stops. The most
important feature may be the patented "Power Sharing" technology which provides
for evenly distributed power to the heating elements. This in turn, helps
eliminate scalding potential, scaling and sediment build-up.
Control
Logic
The control logic allows the power level to vary which is
beneficial in minimizing the use of power for periods of less demanding usage.
Quality
Construction:
Seisco heating chambers are
modular and molded of light weight thermoplastic materials. The chamber is
specifically engineered for durability in harsh water heating environments and
capable of withstanding extreme temperature swings and pressure changes. Heating
elements, sensors and detection devices that come in contact with the water, are
machined in brass or made of copper to help resist corrosion. Standard 1 inch,
flanged screw-type heating elements are utilized which are interchangeable with
heating elements available at local hardware stores.
*NOTE: RA models are designed
for residential applications. If used in a commercial application, the
factory warranty is voided; if used with 208 volt [AC] operation, the available
voltage and therefore the temperature rise are derated by 25%. Commercial units
are available with full factory warranty in 240V and 208V. [Call for details 800
333 9276]
SAFETY FEATURES:
Seisco was designed with a
complete array of dependable safety features to prevent harm to the user and the
heater. There are several redundant safety features as well.
Dual high
temperature switches on independent circuitry in addition to the
control's internal high temperature shut down.
Dual low level
detectors are used to prevent dry firing of the heating
elements.
A leak detector is mounted on the casing that in the
event of a leak sounds an alarm to the user.
Electrical Surge
Protection - Although the control board is protected against electrical
surges, additional heater protection is achieved when the relays are opened
during periods of standby, providing no path for the surge to reach the heating
elements.
Venting System - The chamber is designed with a patented
venting system that continuously vents harmful gasses and air during operation.
The
microprocessor control is programmed to provide self diagnostics that
significantly reduces troubleshooting and service time. In the event of a
problem with the heater, the control emits a visual or optional built-in audible
code.
There is no maintenance required of the Seisco. However, there are
clean-out plates below the heater chamber to allow removal of sand and grit that
may build-up from a well water system.
_________________________________________________________
HELP ป Contact Customer
Support
Toll-Free help
line offering product info and ordering support
Online e-mail technical and installation support
_________________________________________________________
General
Information for all RA models:
Power Rating:
The four-chamber
models contain four electric heating elements whose combined wattage is the
total power rating of the heater. For instance, the standard RA-28 model
contains four 7000 watt elements for a total of 28,000 watts, or 28 kilowatts
(kW) of power. The two-chamber model, RA-14, contains only two 7000 watt
elements for a total power rating of 14,000 watts, or 14 kilowatts (kW).
However, because of Seisco's "Power Sharing" technology, the heater may not
always use the maximum available power. The power output can vary with flow rate
and temperature rise. Refer to the Product Specifications Table above for the
maximum power ratings of each model.
Heating
Output:
The heating output of the Seisco is simply the total
kilowatt power rating of the combined heating elements converted to BTUs using
3,413 BTU/kW. For instance, the RA-28 has a total power rating of 28 kW or a
95,564 BTU heat output rating. The four-chamber models have the higher output
ratings; 61,434 BTUs for the RA-18 model, and 75,086 BTUs for the RA-22 model.
The lower output two-chamber models, are; 47,782 BTUs for the RA-14, 37,543 BTUs
for the RA-11, and 30,717 BTUs for the RA-9. These ratings vary with the
operating voltage or service voltage to the heater. Refer to the Product
Specifications Table for the BTU ratings of each model.
Voltage
Rating:
Seisco heaters are manufactured with common 240 volt
[AC] heating elements designed for optimum operation on a standard residential
240 volt [AC] electric service. Also, the Seisco will operate at 208 VAC, a
typical commercial voltage, with standard 240 VAC heating elements. However,
when operating the heater at 208 VAC, the power rating and the heat output
rating is significantly reduced. Seisco models can be special ordered with 208
VAC heating elements to help maximize the power and heating output. Refer to the
Product Specifications Table above for details on the various voltage
ratings.
Maximum Current Rating:
Each Seisco
Model has a maximum electrical current rating [or amp rating] equivalent to the
sum of the heating element ratings. For example, a four-chamber model, RA-28,
operating at 240 VAC has four heating elements, each with a maximum rating of 29
amps. The maximum current rating or total current rating of the RA-28 is
therefore 116 amps or the sum of the four heating elements. However, because of
Seisco's "Power Modulating Technology", the actual current measured during
relatively low flow rates and/or low temperature rises can be less than the
maximum rating of the heater during operation. Refer to the A [max] or maximum
amp rating under "Electrical" in the Product Specifications Table above for each
model.
Temperature Rise:
The temperature rise must
be determined in order to help choose the appropriate Seisco heater. The rise
can be determined by knowing the input water temperature and the desired output
temperature of the heater. The Seisco's output temperature is typically set for
about 120 degrees F at the factory. Therefore, if the input or cold water inlet
temperature is 50 degrees F, then the temperature rise is the difference or 70
degrees F. If the desired output temperature is 125 degrees F, then the
temperature rise would be 75 degrees F. With the temperature rise determined,
the Product Specification Table above provides the associated flow rate capacity
of the various Seisco models.
Flow Rates:
The flow rate for each model is given in the
"Temperature Rise" section of the Product Specification Table above. Along
with the temperature rise, the flow rate must also be determined in order to
choose the appropriate Seisco heater. The flow rate is determined by the type of
faucet and also, life style. Refer to the chart below for typical faucet flow
rates in the home. However, if the desired life style in the home requires
running multiple faucets at the same time, then the flow rates must be added
together to determine the peak flow demand. The Seisco or the possibility of
multiple Seiscos should be selected to match the peak flow rate.
Below are typical flow rates for new residential construction. There may be
exceptions with new designer type fixtures and faucets. For instance, large
custom body spa showers whirl pool and Jacuzzi tubs may have faucets with flow
rates ranging from 7 gpm to 14 gpm. However, a combination of multiple Seisco
heaters [preferably plumbed in a parallel configuration] can be installed to
match these higher flow rates. The same peak design approach would be necessary
for the anticipated life style of multiple flow rates occurring at the same
time. Otherwise, use the table below and match the Seisco according to the peak
flow and associated temperature rise of a single tub or shower.
Typical Flow Rates in
Gallons per Minute [gpm] |
Fixture
Type |
Lavatory |
Bathtub |
Shower |
Kitchen Sink |
Pantry Sink |
Laundry Sink |
Dish-washer |
Flow Rates |
0.8
-
1.5 |
2.0
-
4.0 |
1.5
-
3.0 |
1.0
-
1.5 |
1.5
-
2.5 |
2.5
-
3.0 |
2.0
-
3.0
|
MORE ป Additional Product
Information
Download ป Seisco Brochures, Data Sheets, Guides, Manuals
_________________________________________________
Product
Manufacturer: Seisco
Return Policy
All
Tankless Water Heaters are tested at the factory just prior to shipment. It is
the customer's responsibility to determine if sufficient electrical capacity
exists to install the water heater prior to placing the order [See Tankless
Water Heater Installation Guide]. Unit sizing must be determined by the customer
using the temperature rise chart based on the required flow rate.
A 20% restocking fee will be applied to returns of new
units in original packaging (see policy page for instructions). The shipping
cost will not be refunded. Once the Tankless Heater has been installed it cannot
be returned.
Processing and Delivery Information: Please allow Processing
Time as stated above for your order, plus standard transportation delivery
time. Orders placed after 2PM EST may not begin processing until the next
business day. Please call for Rush Processing and/or Rush Shipping
options.