Includes control unit, power cord, and sensors. Please click below for other options:Control Unit Control Unit with power cordControl Unit with sensors
Goldline GL-30-LCO Solar Control Package with Power Cord and Sensors - 110 VoltsThe Goldline GL-30-LCO differential temperature control is designed to provide maximum operating efficiency and flexibility to effectively manage today's innovative solar energy systems. It is a continuation of the advanced electronic technology which produced the popular C-30 and CM-30 controllers - standards of the solar industry since 1975, with hundreds of thousands of units installed worldwide. With an adjustable high limit of 50º-104ºF, the GL-30 is capable of handling most differential temperature control functions for operation of domestic water heating and sophisticated space heating and cooling. The GL-30 is designed to control recirculation, drain-back and closed loop systems.
Replacement unit for CM30 and C30:• Includes control unit, power cord, and sensors NOTE: TD-GL & DIX-30 Temperature Displays are discontinued LED IndicatorsThree highly visible LEDs show:• Power to control • Power out from control• Power out from control due to a recirculation mode to protect • the system from freeze damage.GL-30 OutputThe GL-30 output is rated at 20 Amps and is designed to directly operate a pump or fan for heat collection when the controller is sensing an appropriate temperature differential.DifferentialThe GL-30 has an adjustable differential with a range of 8º to 24ºF. Solar systems with long pipe runs normally require a higher turn-on differential temperature, and open loop systems with short pipe runs usually require a lower turn-on differential temperature for optimum performance. The GL-30 offers versatility to tailor controls to numerous specific systems designs.Storage High LimitThe GL-30 allows you to set a high limit storage temperature from 110º to 230ºF.Recirculation Freeze ProtectionRecirculation freeze protection, when enabled, turns the GL-30 output on to circulate warmer storage water through the collectors when near freezing temperatures are reached at the collector sensor.System Test SwitchThe system test switch manually switches the GL-30 to ON, AUTO, or OFF for complete control over the system at all times.Product Application: Solar Domestic Water Heating System_______________________________________________________HELP » Contact Customer Support• Toll-Free help line offering product info and ordering support• Online e-mail technical and installation support_______________________________________________________A complete typical solar domestic water heating system components and layout is shown below.Product Features:• Differential temperature control • 8-20ºF adjustable turn-on differential • 4ºF fixed turn-off differential • 110-230ºF adjustable high limit • 120/240 VAC input • 20A, 2HP output Product Specifications:• Input power: 120 VAC or 240 VAC• Output: SPDT powered contacts 1HP@115VAC, 2HP@240VAC• rating @ 240VAC: 20A on NO contacts ; 10A on NC contacts• Differential: 8/4 to 24/4°F• High Limit: 110° to 230° F• Environment: 15° to 130° F; 0 to 95% rH• Accuracy: +/- 1°F • Dimensions: 5.875" x 4.875" x 2.375"• Temperature Sensors: Thermistor 10k @ 25°C/77°F not includedInside view of the circuit boardProduct Installation: View the following manual for installation and troubleshooting Download » Installation ManualDownload » Goldline WarrantyGeneral Control and Sensor Trouble-Shooting Tips:All of the GoldLine (formally Independent Energy) controls (including C30, CM30, G30 and GL30 series) and some of the Heliotrope General (HG) DTT series controls incorporated the use of 10k sensors. Some of the earlier HG controls and some other lesser known brands used 3k sensors.To determine the type of sensor, the resistance must be measured in ohms (using a volt/ohm meter) when the sensor is at 77 degrees F. 10k measures 10,000 ohms and 3k measures 3,000 ohms. As the temperature goes up, the resistance goes down. Resistance can be checked at any temperature, and then convert the ohm reading measured to the temperature equivalent by using the conversion chart.Sensors can be purchased at Water Heaters Parts and SuppliesProduct Manufacturer: Goldline Controls Inc.Product Warranty: 10 Year Limited WarrantyGoldline Controls Inc. now offers a full 10 year limitedwarranty on all solar controls and accessories! This warrantywill cover repair or replacement of the control at no cost forthe first 24 months. For years 3 through 5, the repair/replacement fee will be a maximum of 25% of the current listprice, and for years 6 through 10, the repair/replacement feewill be a maximum of 50% of the current list price. The bestcontrols now have the best warranty. See the Goldline warranty statement for detail._______________________________________________________
Processing and Delivery Information: Please allow Processing Time as stated above for your order, plus standard transportation delivery time. Orders placed after 2PM EST may not begin processing until the next business day. Please call for Rush Processing and/or Rush Shipping options.