See new Freeze protection Valve with improved features: here  
 Invensys/Eaton/Dole
Invensys/Eaton/Dole 
 Lead-Free 
Freeze  Protection Valve 
Model FP35-SE-2
• 
Valve opening up to 38 degrees 
WARNING: See critical warning below relating to  
proper selection of valve model related to application. 
The Invensys FP Freeze Protection Valves utilize a reliable  
self-contained Dole Power Element which is sensitive to temperature and 
 operates  without any electrical power or sensors. Typically in solar 
 applications, the  valve port opens on descending temperatures allowing the 
near  freezing water in  the solar panel to be discharged and replaced with 
warmer  supply water. When the  warmer water reaches the valve, the port closes 
and  water discharge  stops.
This cycle will repeat as often as necessary 
to  help prevent  freezing. The amount of water dispensed depends mainly on 
ambient  air  temperature, make up water temperature, the duration of the cold 
spell and  the  number and size of collectors. The system is functioning 
properly when  water is  being discharged from the valve during near freezing 
conditions. For  water to be  discharged at the time of operation, system water 
pressure must be  maintained.  
Product Application: 
Solar Domestic Water  Heating  System
Product Function: 
Protects solar  collectors and  exposed piping from freezing 
Product  Features:
• 
Easily installed on  existing systems
• 150 PSI 
maximum operating  pressure
• Corrosion  
resistant design
• FDA and NSF listed  
materials
• LA testing and IAPMO listed
• Anti-siphon and alternate discharge port
• Discharge port for 1/4" plastic pipe or 5/8" ID  
hose
• 1/2" brass male pipe thread inlet port  
for positive seal
• Tamper resistant  
design
• Nominal start to open temperature is 38 
ºF
• Completely mechanical operating  
principle
• High temperature UV stabilized body  
material
• Ideal for backup freeze  
protection
• 1-Year Limited Factory Warranty -   
see warranty details below
 
 
 
 
_______________________________________________________
HELP 
  » Contact Customer  
Support
• Toll-Free 
 help  line offering product info and ordering support
• Online e-mail technical and installation  
support
_______________________________________________________
A  
typical solar domestic water heating system components and layout is shown  
below.

Freeze Protection Valve Application  
Considerations:
1. The Invensys "Freeze  
Protection Valve(s)" functions properly
provided the valve is installed in a  
location, where during operation, the warmer supply water first passes through 
the collectors and/or pipe to be protected and then through the valve. The  
"Freeze Protection Valve(s)" should be located in a position to allow good  
water  distribution through the solar panel
so that when the valve opens,  
water  flows as evenly as possible through all the collector tubes. Location of  
the  valve may vary depending on the system design and piping.
2. IMPORTANT INSTALLATION NOTES: Select a mounting 
position where the valve  will sense the coldest anticipated ambient 
temperature. When used in  conjunction  with active systems, the valve should 
also be located within close  proximity of  the collector outlet with 2"-6" 
offset below the collector header  (see  illustration). Do not mount in a 
position where the valve will be exposed  to an  unnatural heat source (i.e. 
poorly insulated roof, dryer or furnace  vents, etc).  The plumbing from the 
collector outlet to the point where it penetrates the roof  should be insulated 
(this will prevent heat loss, and  protect the piping from  freeze damage in 
cold temperatures).  The Freeze  Protection Valve must be  connected to the 
main return line from a tee fitting  and have 8”-10” of copper  piping between 
the tee and the valve – this section  of pipe must NOT be  insulated, and must 
be painted black to properly simulate  the collector sensing  outside 
temperature conditions.  This section of  pipe should be no less  than 1/2” 
diameter, and preferably be 3/4” diameter  (even if the main return  line is 
only 1/2” diameter) to provide maximum surface  area to sense outside  
temperature conditions.  This section of pipe must  be 1”-2” below the  
outlet pipe to prevent exposure to high temperatures that  can develop near the  
collector outlet (see  illustration).
3. The system must 
be subjected to normal  operating pressures of
between 20 and 125 PSI at all 
times for the valve to  operate properly. Do not shut off water supply to the 
collectors or isolate the  collectors from the city water 
supply.
4. When a check valves is required in the return 
line, be sure it is operating and installed in a proper location with respect to 
the Freeze Protection Valve. Water flow must be prevented from “bypassing” the 
collector. If the check valve leaks internally and does not properly seat, water 
flow may be bypassed through the check valve rather than through the 
collector.
5. Do not insulate the Freeze Protection Valve or exposed 
pipe between the collector return line and the Freeze Protection Valve. Any 
other section of exposed pipe where no water flow exists during valve operation 
should be heavily insulated.
6. Install by applying 
torque with a wrench to the  square metal inlet flange. Do  not apply torque to 
the plastic  body.
7. For proper utilization of the 
anti-siphon port, the Freeze Protection Valve should be installed in a vertical 
position with discharge port down.  To prevent wasps or other insects from 
nesting inside the discharge port which could cause blockage of water flow, wire 
or plastic screen (not included) can be placed over the openings and 
secured.  Be sure that the screen will not interfere with discharging 
water.
8. To enhance  customer satisfaction of this  
product, we recommend a plastic discharge tube be  connected to the 1/4" pipe  
threads or the 5/8" barbs, then routed to a safe,  nonobjectionable location  
where the discharged water will drain.
9. If a discharge 
 tube is used, make sure it  will drain freely and is installed in accordance to 
 local codes. Avoid water  traps in the discharge tube that could freeze and  
prevent drainage. The valve  has an alternate path for discharge water flow  
should the discharge tube become  impaired.
10. Do not  
attempt to disassemble the top  cover. The inlet retention flange can be removed 
 to inspect the screen for  periodic cleaning and  
replacement.
_______________________________________________________
Product 
 Manufacturer: Invensys Appliance Controls.
Manufacturer 
 Warranty: 
Dole/Invensys Energy Control Products are warranted by  
the manufacturer to be free from defects in material and workmanship for a  
period of one year from the date of installation, when properly installed and  
used in accordance with the installation instructions.
Invensys  
obligation is limited to the repair or exchange of the defective parts and does  
not include reimbursement for any removal or installation expenses.
To  
make a claim under this warranty please contact Solar Direct for return  
instructions. This warranty is in lieu of all warranties expressed or implied,  
including warranties of merchantability and fitness for a particular  
purchase.
NOTE: During cold weather, it is normal for  
the valve to dispense water from its discharge port even when ambient air  
temperatures are several degrees above  
freezing.
_______________________________________________________ 
WARNING: Solar collectors can reach internal  
temperatures up to 10 degrees below the outside ambient air temperature.  
Standard Active Open Loop Solar Systems typically require a model FP45 valve to  
ensure proper protection. Passive Batch or Integrated Collector Storage (ICS)  
systems such as the ProgressivTube have a much larger volume and mass of stored  
water, and will not freeze as quickly as a Active Open Loop Solar System,  
therefore they can typically utilize a model FP35 valve. This condition results  
from a phenomenon known as “night-sky emissivity”. The emissivity of a material  
is the ratio of energy radiated by the material (solar panel) to energy 
 radiated  (or absorbed) by a black body (the sky); it is a measure of a 
 material's ability  to absorb and radiate energy. Since solar collectors are 
 coated with a black  surface they are very good at conducting and emitting 
 energy. When the outside  temperature approaches freezing, the surface of the 
 solar collector begins to  emit energy to the night sky. When the atmosphere is 
 clear with no clouds, the  transfer of energy is accelerated. In layman terms, 
 this means that on a cold  clear night, the water in the solar panel can be up 
 to 10 degrees colder than  the outside temperature. A Freeze Protection Valve 
needs to begin opening when  the outside temperature drops to 42 degrees and 
 below. As the temperature drops  from 42 to 32 the volume of water discharged 
 from the valve increases. Consult  the owner’s manual of your collector and/or 
 system to determine the correct  valve model to use; Solar Direct and/or The 
 Energy Supermarket makes no claim as  to the correct valve to use, and/or its 
usage and application; and assumes no  liability for damages resulting from 
 correct or incorrect use of this product.  
 
Processing and Delivery Information: Please allow Processing  
Time as stated above for your order, plus standard transportation delivery  
time. Orders placed after 2PM EST may not begin processing until the next  
business day. Please call for Rush Processing and/or Rush Shipping  
options.