Surplus item to be discontinued. 1 Year warranty from JED  
Engineering. 
    3-Way FloVerter Motorized Valve Model: 
FV-2.0
  The FloVerter 24VAC valve works  in 
conjunction with either HelioMatic  electronic controller model. 
  When the controller is signaled by the sensors, and calls for solar heat 
pick-up, the FloVerter valve immediately activates. The opening "diverter" valve 
then directs the flow of circulation through the solar collectors using the 
pool's filtration pump. 
  The FloVerter valve is a 24VAC 2" I.D. 
valve, utilizes permanent magnetic synchronous motors, and has an 
extremely low CV.* 
  Technical Specifications: The 
FloVerter is a non-positive seal  valve with a small hole located 
in the diverter, which allows the collector to drain when the system is turned 
off. This draining prevents collector  damage due to cold weather freeze-ups. 
  FloVerter's Unique Features:  • Low profile design utilizes two synchronous motors 
to direct flow  • Constructed 
using twin O-Rings that provide superior service  • Diverter designed with curved and fluted channel 
for reduced pressure  • Unibody 
valve/actuator require no assembly; actuator easily replaced  • Manual control over-ride always available using 
sure-grip handle  • Color-coded wire 
terminals make connecting to controller a breeze!  • Non-positive seal for freeze protection; positive seal 
available  • The FloVerter never needs 
lubrication, and may be mounted in any  • 
position except upside down 
  Note: For a positive 
solar shutdown, or service to collectors during  pump operation cycle, an 
isolation ball or gate valve must be used on  the feed line for positive shut 
off. 
  *The extremely low Constant Velocity factor is due to 
the unique  curved and directed flow channel inside the diverter.  
The FloVerter valve is better than ever! 
A number of changes have been made to the Flo-Verter valve to make it even 
more reliable! Every component of the Flo-Verter valve has been analyzed and 
reevaluated.  To further enhance the performance of the Flo-Verter, a 
number of positive changes have been made.   
• The motor mounts of the actuator motors are 
now thru bolted.  • The wire terminal splices 
are soldered at the factory.   • The 
actuator shaft is manufactured to upgrade tolerances with • Lubricomp 
and sealed with silicone to prevent the build-up  • 
of chlorine gases. • The Model ‘D’ 
controllers have a delay module built into the circuitry • to 
block spikes and voltages that might cause the valve to stop part • way to collection. 
How is the Flo-Verter valve different from others? 
The Flo-Verter valve looks pleasingly different from other motorized valves 
at the plumbing site of the pool.  The homeowner can simply observe the 
arrow shaped valve handle and determine that pool water flow is going to the 
collectors, giving them confidence that solar heat collection is taking place. 
There is not a toggle switch on the Flo-Verter valve that can easily be left in 
the wrong position thereby eliminating costly service calls. The handle on the 
Flo-Verter valve allows the home owner or service personnel to manually change 
the direction of water flow.  If left in a position not commanded by the 
controller, the valve position will be automatically corrected the next 
collection cycle. 
____________________________________________________________  
  FloVerter Technical Notes: Installation is 
simplified as one  port is easily identified with a "FLOW TO COLLECTOR" 
symbol. 
  An adequate length of three wire color coded cable is 
permanently  attached to the FloVerter valve and these three wires connect to 
the  color identified terminals on the HelioMatic controller. There is 
never  a need to check flow direction as an error is impossible if the same 
 colors are connected together. 
  The FloVerter is a non-positive seal 
valve and the diverter has  a small hole, which allows the collector to drain 
when the system is off.  This draining prevents collector damage due to 
freeze ups. 
  Note: For a positive solar shutdown, or 
service to collectors during  pump operation cycle, an isolation ball or gate 
valve must be used on  the feed line for positive shut off.  
 Heliotrope Pool Flo-Verter Valve 
Installation 
 __________________________________________________________ 
 
       
HELP » Contact Customer 
Support       
• Toll-Free help line offering unit selection assistance      • 
Online e-mail technical and installation support 
  __________________________________________________________  
Note: All product performance tests and claims are that of 
the  manufacturer, not The Energy Supermarket.   
Processing and Delivery Information: Please allow Processing 
Time as stated above for your order, plus standard transportation delivery 
time. Orders placed after 2PM EST may not begin processing until the next 
business day. Please call for Rush Processing and/or Rush Shipping 
options.
 
   
           |